Veterinary Refrigerated Centrifuges
High-performance veterinary refrigerated centrifuges for heat-sensitive samples.
Maintain biological integrity from -20°C to +40°C.
Ideal for animal vaccine research, blood banking, and advanced equine therapeutics.
PRODUCT DETAILS
In advanced veterinary diagnostics and biopharmaceutical research, maintaining a stable temperature is as critical as centrifugal force. Our Veterinary Refrigerated Centrifuges are specifically engineered for thermolabile samples—such as enzymes, vaccines, and delicate blood components—that would otherwise degrade due to the heat generated during high-speed rotation.
By combining powerful refrigeration systems with precision motor drives, these units ensure that every run remains within a strict temperature range, providing the repeatable results necessary for critical animal health decisions and scientific breakthroughs.
Advantages for Veterinary Refrigerated Centrifuges
1. Precise Temperature Stabilization (-20°C to +40°C)
Equipped with high-efficiency, CFC-free refrigeration compressors, our units can maintain a constant 4°C even at maximum rotational speeds. The Pre-cooling function allows the rotor chamber to reach the desired temperature before you even load your samples, ensuring no thermal shock to sensitive biologicals.
2. High-Speed Performance with Dynamic Cooling
Our refrigerated series supports speeds up to 16,000+ RPM (approx.[5][6][7] 25,000 xg), making them suitable for:
Molecular Diagnostics: DNA/RNA extraction for infectious disease testing.
Protein Purification: Isolate specific proteins from animal serum without denaturation.
Virus Concentration: Essential for veterinary virology and vaccine development.
3. Whisper-Quiet & Vibration-Free Operation
We understand that many veterinary labs are located within clinics. Our units feature enhanced acoustic insulation and a brushless induction motor, keeping noise levels below 55dB. This minimizes stress for nearby patients and provides a better working environment for technicians.
Technical parameter
Model | CLT55R | CLT55 |
Order NO | 0204260029 | 0205255026 |
Max Speed | 5500r/min | 5500r/min |
Max RCF | 4904xg | 4904xg |
Max Capacity | 4x750ml | 4x750ml |
Speed Accuracy | ±10r/min | ±10r/min |
Time Setting Range | 1s~99min59s、1min~99h59min | 1s~99min59s、1min~99h59min |
Timing mode | start timing ,speed timing and continuous timing. | start timing ,speed timing and continuous timing |
Temperature Setting Range | -20~40° | / |
Temperature Accuracy | ±0.5°℃ | / |
Pre-cooling function | yes | / |
Compressor Unit | High performance compressor unit ,Environment-friendly refrigerant (134a) | / |
Noise | ≤65dB(A) | ≤65dB(A) |
Short Spinning | yes | yes |
Rotor Identification | yes | yes |
Power Supply | AC 220+22V 50/60Hz | AC 220+22V 50/60Hz |
Power Consumption | 1.6kW | 900W |
Dimension | 713x681x398(mm) | 510x635x398(mm) |
Packing Dimension | 860x810x620(mm) | 660x770x450(mm) |
Net Weight | 95kg | 76kg |
Rotor parameters
| Rotor Type: Angle Rotor Max Capacity: 40x15ml Max Speed: 5500r/min Max RCF: 4904xg Order No:0301891144 | can be customized |
|
|
|
Rotor Type: swing Rotor (Automatic de-capping ) Max Speed: 4000r/min Max RCF:3370xg Max Capacity:120pcs(13x75/100mm) Order No:0302891036 | Brackets Order No:0303891059 | Adapter Specification: 13x75/100mm tube Order NO:0304854020 |
Rotor | Bucket | Adaptor | Capacity/Order NO | Adaptor | Capacity/Order NO |
Rotor Type: Swing Rotor Max Speed: 4000r/min Max RCF: 3345xg Max Capacity: 4x500ml Order No:0302850110 (Bucket not included) |
Round Bucket Order No: 0303891022
Aerosol-tight round bucket Order NO: 0303891077 |
| 4x1x250ml 0304891142 |
| 4x2x100ml 0304891009 |
| 4x4x50ml (conical/round) 0304891008 |
| 4x7x20ml 0304851485 | ||
| 4x9x15ml (conical/round) 0304891083 |
| 4x11x15ml(conical) (Cap≤21.5mm) 0304891508 | ||
| 4x14x10ml 0304891705 |
| 4x19x5/7mlVaccum blood collection tube0304851450 | ||
| 4x36x1.5ml 0304891677 | / | |||
Rectangular Bucket Order No: 0303851421
Rectangular bucket with sealing cover Order No: 0303891016 |
| 4x1x250ml 0304891041 | | 4x3x100ml 0304891744 | |
| 4x6x50ml (conical/round) 0304891014 |
| 4x12x15ml (conical/round) 0304891582(conical) 0304891779(round) | ||
| 4x20x10ml 0304891077 |
| 4x31x5/7mlVaccum blood collection tube 0304891782 | ||
| 4x56x1.5ml 0304891603 | / | |||
can be customized | |||||
Rotor | Bucket | Adaptor | Capacity/Order NO | Adaptor | Capacity/Order NO |
![]()
Rotor Type: Swing Rotor Max Speed: 4000r/min Max RCF: 3500xg Max Capacity:4x750m Order No:0302891036 (Bucket not included) |
Round Bucket Order No: 0303891025
Aerosol-tight round bucket Order No: 0303891006 |
| 4x1x500ml(conical/flat) 0304891035(conical) 0304891036(flat) |
| 4x1x250ml(conical/flat) 0304891562(conical) 0304891039(flat) |
| 4x4x100ml 0304891006 |
| 4x5x50ml (Self-standing tube) 0304891024 | ||
| 4x7x50ml(conical/round) 0304891003(conical) 0304891004(round) |
| 4x10x20ml 0304891163 | ||
| 4x15x15ml(conical) 0304891005 |
| 4x19x10ml (Self-standing tube) 0304891732 | ||
| 4x21x10ml 0304891730 |
| 4x27x5/7mlVaccum blood collection tube 0304891728 | ||
| 4x37x5ml(RIA tube) 0304891166 |
| 4x56x1.5ml 0304891025 | ||
Round Bucket Order No: 0303891025 |
| 4x9x50ml(conical/round) 0304891015(conical) 0304891016(round) |
| 4x19x15ml (conical/round) 0304891012(conical) 0304891704(round) | |
| 4x30x10ml 0304891709 |
| 4x38x5/7mlVaccum blood collection tube 0304891017 | ||
Microplate bucket Order No: 0303891147 | 4x2x96Deep-well plate 4x4x96Microplate Plate height in total≤67mm | ||||
SPECIFICATIONS
Veterinary Refrigerated Centrifuges Applications :
Animal Vaccine Development & Storage
Refrigerated centrifugation is the standard for separating bacterial and viral suspensions during vaccine production. Constant cooling prevents the loss of antigenicity, ensuring the final product's efficacy in protecting livestock and companion animals.
Advanced Equine Blood Banking
In equine sports medicine, processing blood for transfusions or concentrated Platelet-Rich Plasma (PRP) requires strict temperature monitoring to preserve cellular function. Our refrigerated units allow for the safe separation of large volumes (up to 500ml or 1000ml) while protecting platelet viability.
Livestock Breeding & Reproductive Technology
Used extensively in bovine and porcine breeding programs, these centrifuges facilitate the preparation of semen extenders and the concentration of genetic materials under controlled environmental conditions.
Biopsy & Cytology Research
When dealing with delicate tissue aspirates or rare cell populations from exotic species, our refrigerated systems prevent enzymatic degradation during the sedimentation process.
Frequently Asked Questions (FAQ)
Q: Why is refrigeration necessary for veterinary blood samples?
A: Standard centrifugation generates friction heat, which can increase the chamber temperature by 10-15°C. For routine PCV, this may be acceptable, but for enzyme assays, coagulation studies, or hormone testing (like cortisol or insulin), heat will skew results. Refrigeration keeps samples at a physiological 4°C, mirroring the "cold chain" required for accurate lab data.
Q: Can I use this unit for both micro-tubes and large-volume bottles?
A: Yes. Our refrigerated series is designed for versatility. By simply swapping the rotor or using our specialized adaptors, you can switch from 24 x 1.5ml microtubes for molecular work to 4 x 250ml bottles for bulk blood processing.
Q: How does the "ECO-mode" or "Standby Cooling" work?
A: To save energy and prolong the life of the compressor, the unit can be set to "Standby Cooling." This keeps the chamber at your target temperature while the lid is closed but the motor is off, so the centrifuge is ready for immediate use without waiting for a pre-cool cycle.
Q: What maintenance is required for the cooling system?
A: We recommend a monthly check of the condenser fins for dust buildup and ensuring the drainage hole is clear of condensation. These simple steps ensure your iVetWell centrifuge maintains its cooling efficiency for years.